Maximum water pumping speed for increased throughput
Water Vapour Pumping
The Polycold MaxCool 4000 H cryochiller effectively captures water vapour, which comprises 65% to 95% of the residual gas in high vacuum systems.
Water vapour is typically the most reactive contaminant present. With the MaxCool Cryochiller, you can expect to increase product throughput in your existing system 20% to 100% and improve quality of deposition.
The MaxCool Advantage
- High-vacuum pumpdown time cut by up to 75%
- High-speed pumping of water vapour: 10,000 to 220,000 l/sec in the workspace
- Increased product throughput of 20% to 100%
- Lower water vapour partial pressure during processing for higher film quality, better adhesion and more reproducible deposition
- Superior in cost/performance to liquid nitrogen cooled Meissners
- Minimize cost of ownership with power management
- High capacity cooling and heating for a wide variety of processes
When added to your vacuum system, the MaxCool Cryochiller can dramatically reduce pumpdown times and increase product throughput. The MaxCool will pump water vapour within minutes from “start” and can defrost in less than four minutes, giving true fast-cycle capability. It also has an option called Rapid Cool to Cool which eliminates the waiting period after defrost. For your system, this means more production cycles per shift.
Using patented Polycold® refrigerant mixtures, the MaxCool works on the principle of Meissner trapping. Water vapour is captured by condensation on a cryogenically cooled surface, called a Meissner coil. The Meissner (cryocoil) is mounted directly in the vacuum chamber so conductance is not limited by ports, manifolds, valves, and baffles. The cryocoil is easy to install and can be adapted to fit any system.
It does not need a high vacuum valve.
MaxCool Cryochillers are the most cost effective upgrade that you can add to any diffusion-pumped, turbo-pumped, or helium-cryopumped system.
MaxCool Cryochillers are compliant with European Application Refrigerants (EC 1005/2009), the Montreal Protocol, and the US EPA SNAP.
Benefits
- -98 to -133C (183 to 140K)
- Heat Removal to 4000 watts
- Cryocondenses Water Vapour in Vacuum Systems with Speeds to 220,000 l/sec Vacuum levels to 5 x 10-8 torr (7 x 10-8 mbar)
- Theoretical maximum pumping speed 328,000 l/s
- Increased productivity with rapid cool to cool option
- Option for power management to minimize cost of ownership
- Temperature control
- Patented Green refrigerant charge is globally compliant, non-toxic, and non-flammable
- Based on Polycold proven, innovative, dependable mixed gas refrigeration
- Compliant to EU PED and MD
- TUV Rheinland Listed to NRTL/CANADA Safety Standards
- ISO 9001:2008 certified manufacturer